UL L502, UL L515, UL L533, UL L545, UL L569, UL L590, UL M532, UL M535

  • Stc

    53
  • Clasificación de resistencia al fuego

    1 Hour
  • Espesor del sistema

    12 in
  • Stc 53
  • Fire Rating 1 Hour
  • System Thickness 12"
Detalles de las estructuras
  • Finish Flooring

    0.1" [2.5 mm] Sheet Vinyl (by others) with 0.04" padded backer

  • Floor underlayment panels

    Two 1/4" [6.3 mm] USG Fiberock® Brand Interior Panels

  • Sound Attenuation Mat

    5/16" [8 mm] KINETICS® Soundmatt Sound Control Underlayment

  • Structural Cement-Fiber Unit

    3/4" [19 mm] STRUCTO-CRETE® PANEL (UL TYPES USGSP, STRUCTO-CRETE)

  • Structure

    6" [152 mm] W6 x 9, min size, 50 ksi steel OR min 6" [154 mm] Hollow Structural Sections (HSS) with 50 ksi steel

  • Structure

    6" [154 mm] Steel "C"Joist @ 24" [610 mm] o.c.

  • temperaturas

    3-1/2" [89 mm] Knauf EcoBatt R-13 glass fiber batt insulation

  • Wire Netting

    Hexagonal Wire Netting

  • Structure

    3/4" [19 mm] Steel plate, minimum 4" [101.6 mm] by 4" [101.6 mm] by 3/4" [19 mm] thick. Attached to structure per UL.

  • Structure

    4" [101.6 mm] W4 x 13, min size, 50 ksi steel min. Hollow Structural Sections (HSS)

  • Structure

    4" [101.6 mm] Steel "C"Joist @ 24" [610 mm] o.c.

  • Resilient Channel

    1/2" [12.7 mm] resilient channel, 25 ga. (0.018"), spaced 12" [305 mm] O.C. max.

  • Gypsum Panel

    5/8" [15.9 mm] Sheetrock® EcoSmart Gypsum Panel (UL Type ULIX™)

Notes
View assembly information on UL Website.
COMPATIBLE PRODUCTS
Available insulation products for UL L502, UL L515, UL L533, UL L545, UL L569, UL L590, UL M532, UL M535.