UL U423, U425
Interior Partitions, Steel Stud (Load-Bearing)

  • Stc

    0
  • Fire Rating

    1 Hour
  • System Thickness

    4-3/4"
  • Stc 0
  • Fire Rating 1 Hour
  • System Thickness 4-3/4"
Assembly Details
  • Floor/Ceiling Runners
    Channel-Shaped, 3-1/2" min. wide with 1-1/2" min. legs, fabricated from No. 20 GA. Min. (0.0329" min. Bare Metal Thickness) Corrosion Resistant Steel. Attached to floor and ceiling with steel fasteners spaced not greater than 24"
  • Gypsum Board
    5/8" thick Gypsum Board (UL Type ULIX™)
  • Steel Studs
    3-1/2" Steel Studs, 20ga. MSG., Spaced 24" O.C.
  • Insulation
    3-1/2" thick Knauf EcoBatt Insulation
  • Lateral Support Members
    Where required for lateral support of Studs, support may be provided by means of Steel Straps, Channels or other similar means as specified in the design of a particular Steel Stud Wall System (not shown)
  • Gypsum Board
    5/8" thick Gypsum Board (UL Type ULIX™)
Notes
View assembly information on UL Website.
Compatible Products
Available insulation products for UL U423, U425.
Performance+™ EcoBatt® Insulation
Quality engineered thermal and acoustical fiberglass batt insulation with innovative ECOSE® technology is ideal for floors, walls, ceilings and attics.
Thickness
2.5" - 13.75"
R-Value
R-8 - R-49
Width
11" - 24"
Ask an Expert
Reach out to our technical support team for product specs, installation guidance and more.
Contact Us